C-Tec FF516 MFP 16 Zone Conventional Fire Alarm Control Panel

In Stock
Delivery within two days all over UAE.

AED 6,851.25

C-Tec FF516 MFP 16 Zone Conventional Fire Alarm Control Panel designed to comply with BS 5839-4 (this panel is not compliant with EN54-2/4 and should NOT be used in the new UK or European installations). Non-latching class change sounder input, latching fire & non-latching fault outputs (via expansion loom).  Robust metal enclosure c/w lift-off lid & heavy-duty base connections, Up to 8 two-wire Repeaters per the Main panel.

Add to Quote
In Stock
Add to Wishlist
Add to Wishlist

Did you like this product? Add to favorites now and follow the product.

Add to Wishlist
Add to Wishlist
Have a Question? Ask a Specialist

+971 54 581 5314

Free Delivery

Above AED 200

Warranty

For 365 days

Always Authentic

Only Reputed Brands

Easy Payments

Multiple payment options

Description

C-Tec FF516 MFP 16 Zone Conventional Fire Alarm Control Panel designed to comply with BS 5839-4 (this panel is not compliant with EN54-2/4 and should NOT be used in the new UK or European installations). Non-latching class change sounder input, latching fire & non-latching fault outputs (via expansion loom).  Robust metal enclosure c/w lift-off lid & heavy-duty base connections, Up to 8 two-wire Repeaters per the Main panel. Separate indicators for open circuit, short circuit, head-out, sounder & battery/power supply faults, Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range.

Reviews

There are no reviews yet.

Be the first to review “C-Tec FF516 MFP 16 Zone Conventional Fire Alarm Control Panel”

Your email address will not be published. Required fields are marked *

Features

  • Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and shouldNOTbe used in newUK or European installations).
  • Non-latching class change sounder input, latching fire &non-latching fault outputs (via expansion loom)
  • Separate indicators for open circuit, short circuit, head-out, sounder &battery/power supply faults.
  • Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range
  • Zone selectable short circuit=fire facility (pre-1980 BS, no resistors in call points).
  • Robust metal enclosure c/w lift off lid & heavy-duty base connections
  • 16conventional Zone circuits (expandable to 28).
  • Up to 8 two-wire Repeatersper Main panel
  • Multi-lingual variants (subject to quantities)
  • Space for 2x 12V 7Ah VRLA batteries.