Frontier FM200 System – HFC-227ea Fire Extinguishing System
AED 25,000.00
Get a Free Quote Enquire via WhatsAppThe Frontier Fire Systems SP Series Clean Agent Fire Extinguishing System utilizes HFC-227ea gas as its extinguishing medium. It is an engineered solution specifically designed to uniformly mix throughout a protected enclosure to suppress fires within 10 seconds. Because it leaves no residue and is electrically non-conductive, it provides premium, non-toxic protection for high-value assets and occupied spaces.
Note: Listed prices are baseline estimates. Actual project costs depend on total square footage, hazard classification, and specific area containment requirements. Contact our team for a customized quote.
Did you like this product? Add to favorites now and follow the product.
Description
The Frontier Fire Systems SP Series is an advanced, engineered clean agent fire extinguishing system designed to offer rapid and reliable fire suppression. Utilizing HFC-227ea—a colorless, non-toxic, and odorless gas—the system extinguishes fires primarily through heat absorption without leaving any messy residue or damaging sensitive equipment. It consists of specialized storage cylinders, distribution piping, performance-tested nozzles, and an intelligent control panel that monitors everything from detectors to cylinder pressure. This makes it perfectly suited for high-risk, restricted spaces housing electronics, critical infrastructure, and assets where clean-up from traditional fire suppression methods would be highly problematic.
Features
- Rapid Fire Suppression: Engineered to discharge completely into an enclosure within 10 seconds or less. This rapid deployment ensures early fire suppression and actively minimizes the formation of toxic Hydrogen Fluoride (HF) byproducts.
- People and Asset Safe: The clean agent gas (HFC-227ea) is colorless, non-toxic, and electrically non-conductive. It leaves absolutely no residue behind, completely eliminating cleanup damage. It is safe for normally occupied environments and does not affect electronics or common materials like rubber, plastic, steel, brass, copper, and aluminum.
- Scalable Multi-Cylinder Layouts: Supports modular single or interconnected configurations of up to 7 units (1 primary master cylinder alongside up to 6 slave cylinders) utilizing heavy-duty 6 mm rubber pilot hoses to cover highly extended spaces.
- Uniform Area Dispersion: Equipped with performance-tested 360-degree radial (8-port) or 180-degree sidewall discharge nozzles to provide exceptional gas mixing and distribution throughout the protected hazard.
- Active Security Monitoring: Incorporates an intelligent control panel that constantly supervises the functional integrity of electric solenoid actuators, optical/thermal detectors, warning signals, internal gas pressure, and emergency manual release overrides.
Specifications
1. Agent & Storage Profile
- Extinguishing Agent: HFC-227ea / Heptafluoropropane (CF3CHFCF3).
- Primary Extinguishing Mechanism: Heat absorption paired with a secondary chemical interaction from thermal decomposition inside the flame.
- Storage Fill Density Range: 480 kg/m3 to 1121 kg/m3.
- Superpressurization Medium: Superpressurized with dry nitrogen gas.
- Nominal Working Pressures: Available in 25 Bar or 42 Bar options (measured at 21°C).
2. Cylinder Configurations
- Cylinder Volumetric Capacities: Broad range including 40L, 50L, 60L, 70L, 80L, 90L, 100L, 120L, 150L, 160L, and 170L sizes.
- Manufacturing Standards: Lightweight, vertical-mounting steel cylinders manufactured with a robust welded seam matching TPED requirements.
- Discharge Outlet Sizes: Configurable male thread connection ports available in 1.25-inch (33 mm) or 2-inch (49 mm) profiles depending on model configuration.
3. Valve & Actuation Specifications
- Cylinder Valve Construction: Heavy-duty forged brass operating on differential pressure principles.
- Valve Ports/Connections: Features a 5-point manifold layout consisting of a Valve Actuation Connection, integrated Pressure Gauge Connection (with internal check valve), Discharge Outlet, Pilot Actuation Port (1/4-inch FNPT), and a Safety Release.
- Electrical Solenoid Actuator: Heavy-duty actuator featuring a stainless steel activation pin alongside integrated normally closed (NC) supervisory limit switch contacts that automatically open once fully installed.
- Pneumatic Slave Actuator: Formed from durable brass housing equipped with a solid brass internal piston and activation pin.
- Pneumatic Safety Overrides: Equipped with an optional top-mounted manual valve actuator featuring an emergency release button and a protective safety ring pin.
4. Safety & System Trim Elements
- Anti-Recoil Device: Mandatory safety device factory-installed directly inside the valve discharge outlet to protect operators during decoupled maintenance routines.
- Safety Bleed Valve: Integrated G1/8-inch male threaded safety trim designed to safely vent any slow residual pressure buildup within pilot lines, preventing accidental slave cylinder activation.
- Discharge Pressure Switch: Heavy-duty single-pole double-throw (SPDT) feedback loop switch rated for 10 Amps resistive at 30 VDC to confirm agent discharge and command peripheral equipment shutdowns.
- Manifold Check Valve: Heavy-duty 1.25-inch or 2-inch thread valves installed in shared manifold designs to rigorously block hazardous backward gas flows.
- Nozzle Installation Height Limits: Supports a maximum ceiling/clearance height of 5500 mm per individual tier of deployed nozzles.
Reviews