Honeywell Morley MI-D2ICMOE Dual Input Single Output Module
AED 591.36
Get a Free Quote Enquire via WhatsAppThe Honeywell Morley MI-D2ICMOE Dual Input Single Output Module is an addressable multi-function interface module designed to monitor two dry-contact input channels and control a Form-C volt-free relay output on Morley-IAS fire loops. Featuring integrated short-circuit isolation and rotary decade switches, it simplifies multi-device life-safety integration.
Did you like this product? Add to favorites now and follow the product.
Description
The Honeywell Morley MI-D2ICMOE Dual Input Single Output Module is engineered to maintain safety integrity and deliver multi-channel monitoring and control across commercial, industrial, and institutional fire protection systems. Connected directly to the Morley-IAS addressable communications loop, this versatile module provides two independent, supervised input circuits to monitor external dry-contact devices (such as sprinkler flow switches and valve tamper switches) alongside a single Form-C changeover relay output for auxiliary equipment control (such as elevator recall, HVAC shutdown, or door release). By consolidating multiple I/O channels into a single addressable footprint, it optimizes loop address capacity and reduces field wiring complexity. Equipped with onboard short-circuit loop isolation, rotary decade switches, and status LEDs, the MI-D2ICMOE complies fully with EN 54 safety standards.
Features
- Dual supervised input circuits combined with a single volt-free relay output maximize installation efficiency on addressable loops
- Form-C changeover relay provides versatile switching for door release, AHU shutdown, and elevator recall control
- Integrated short-circuit loop isolator protects signaling line continuity against field wiring faults
- Mechanical rotary decade switches enable rapid, foolproof address assignment without dedicated software programmers
- Supervised inputs continuously monitor external equipment status for tamper, fault, and alarm conditions using EOL resistors
Specifications
- Brand: Honeywell Morley-IAS
- Model / Part Number: MI-D2ICMOE
- Product Type: Addressable Dual Input / Single Relay Output Interface Module
- Monitored Input Channels: 2 x Supervised Input Circuits (Monitored for Open and Short Circuit faults via EOL resistors)
- Relay Output Contacts: 1 x Form-C Volt-Free Changeover Contact (NO / NC / COM)
- Contact Rating: 30V DC, 2A (Resistive) / 125V AC, 0.5A (Resistive)
- Loop Communication Protocol: Morley-IAS Intelligent Addressable Protocol
- Operating Voltage Range: 15V DC to 30V DC (Loop Powered)
- Standby Current: ~340 µA @ 24V DC (LED inactive)
- Alarm / Active Current: ~6.5 mA @ 24V DC (LED active)
- Device Addressing: Dual Rotary Decade Switches (occupies consecutive loop addresses)
- End-of-Line Resistor: 47 kOmega EOL Resistor Network per input circuit
- Short-Circuit Isolator: Integrated Loop Short-Circuit Isolation
- Visual Status Indicator: Multi-Status LEDs for Channel Polling, Fault, and Alarm/Active States
- Enclosure Material: Flame-Retardant ABS Plastic (Wall-Mount Surface / DIN Rail Enclosure Options)
- Operating Temperature Range: -20°C to +60°C
- Relative Humidity Range: 5% to 95% RH (Non-condensing)
- Standards & Certification: EN 54-17, EN 54-18 Compliant, LPCB Approved, CE Marked